Surewire SW2L-MF 2way pre-wired light and switch Junction Box (Sure Wire)

Surewire-SW2L-MF-2-Way-Pre-Wired-Light-and-Switch-Junction-Box Sure Wire
This Surewire SW2LMF Pre-wired Maintenance free Light and Switch Junction Box has facility for a feed from the consumer unit or another Surewire junction box.

Apart from the mains feed to this Surewire unit it has 2 sets of switch lines and fitting outputs.

This Surewire unit has been designed for the addition of extra lighting including extensions, conservatories, garages, lofts and outdoor lighting etc. 16amp 250volt. Size 137 x 135 x 22mm


See the Youtube video below:


Main Benefits
Easy to wire and maintain
Less complicated saving time and effort
Reduces the number of terminal connections
All connections are cut and stripped to the same length
Modular and integrates into any system
All cables are strain relieved
Can be used in domestic, commercial and industrial premises
Rated to 16A 250V
Approved to BS EN 60670-22

Other Benefits
Surewire is very simple to wire with the circuit pre-determined and clearly marked on the box.
Each wire has its own terminal connection which is best practice.
Any maintenance or adding additional light switches and light connections is very simple.
The lids have recessed areas where stickers or tape can be fixed to identify the light location.
Screws in the lid are retainable so you don’t lose them when the lid is removed.
The box has cut out tabs so no connection is left open if it’s not being used.
Securing holes in the box base are spaced so it can be secured easily to a standard 3” beam.
If a light connection is no longer required, simply remove the connection. No rewiring required.

How to install
One cable goes from the consumer unit to the junction box P I/O connection, one cable goes from the junction box S connection to the switch and one cable goes from the junction box corresponding L connection to the light. If extra light and switch connections are required, another Surewire junction box can be added in series by using the spare P I/O connection.

To integrate Surewire into current systems, isolate the power, locate the lighting radial power cable, cut the cable and wire to both ends of the Surewire junction box at the P I/O connections. This reinstates the radial power and gives you extra light and switch connections.

Featured in 'Professional Electrician' magazine and online click here.